LLT PRODUCT CATALOGUE

Expand the parameters.
See the connection clearly.

From circular interfaces to splitters, from signal to power. Review catalog parameters, applicability and original source pages by series, then move to specific configuration selection.

Parameters and documentation notes in the expanded content are searchable. Series images are for visual identification; ratings apply per the specific product column and contact count row.

29 series · 80 sets of catalog parameters

M8

For outline and mounting dimensions, see the corresponding original catalog page.

Circular waterproof connectors

M8

Locking: threaded
Termination: wire soldering / overmolded with cable
Mounting: in-line / panel

Series-level options; not every order number includes all of them.

Source: PDF 8 · PDF 9 (printed page 6)

Expand 2 catalog parameter groups
Series brochure page material2 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 8

Applies only to the product row and pin count on that page; not inherited across series

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 8

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 8

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Assembly threaded solder6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
9

Source: PDF 9

Applies only to the product row and pin count on that page; not inherited across series

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Catalog protection rating
IP65 or IP67
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Cable outer diameter, min
3 mm
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Cable outer diameter, max
6.5 mm
Applicability and sources

Applicability

Applicable PDF pages
9

Source: PDF 9

  • IP65/IP67 are optional combinations, not confirmed simultaneously for every SKU; the promotional page shows OD 6.1 mm while the specification page shows 6.5 mm.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M12 series appearance reference

Series appearance reference · does not represent the individual pin positions and dimensions of each configuration.

Circular waterproof connectors

M12

Locking: threaded / quick-latch / bayonet / push-lock
Termination: wire soldering
Mounting: front panel / metal front panel / in-line

Series-level options; not every order number includes all of them.

Source: PDF 16 · PDF 18 (printed page 15)

  • The marketing page's 5 A and IP65 cannot override the specification page's 10 A for 1–4 pins and IP67.
Expand 2 catalog parameter groups
Series brochure page material2 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 16

Applies only to the product row and pin count on that page; not inherited across series

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 16

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 16

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Front-mount panel6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
18

Source: PDF 18

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Maximum panel thickness
3 mm
Applicability and sources

Applicability

Applicable PDF pages
18

Source: PDF 18

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M14 assembly catalog original image

Original catalog image · M14 assembly. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Circular waterproof connectors

M14

Locking: threaded
Termination: wire soldering / overmolded with cable
Mounting: in-line straight / in-line 90-degree / front panel

Series-level options; not every order number includes all of them.

Source: PDF 34 (printed page 31) · PDF 35 (printed page 32) · PDF 36 (printed page 33)

Expand 5 catalog parameter groups
Wire-to-wire4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
34

Source: PDF 34

Applies only to the product row and pin count on that page; not inherited across series

  • This page has no IP rating row; IP ratings cannot be inherited from adjacent series.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
34

Source: PDF 34

  • This page has no IP rating row; IP ratings cannot be inherited from adjacent series.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
34

Source: PDF 34

  • This page has no IP rating row; IP ratings cannot be inherited from adjacent series.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
34

Source: PDF 34

  • This page has no IP rating row; IP ratings cannot be inherited from adjacent series.
Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
34

Source: PDF 34

  • This page has no IP rating row; IP ratings cannot be inherited from adjacent series.
Outer diameter by column1 parameter · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
34

Source: PDF 34

Applies only to the product row and pin count on that page; not inherited across series

Original outer diameter as listed per product
Assembly 3.5–7.5 mm · overmolded straight 3.5–9.0 mm · overmolded 90-degree 3.5–9.0 mm
Applicability and sources

Applicability

Applicable PDF pages
34

Source: PDF 34

Male contact assembly6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Cable outer diameter, max
7.5 mm
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Field assembly

Source: PDF 35

Male contact overmolding6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Cable outer diameter, max
9 mm
Applicability and sources

Applicability

Applicable PDF pages
35
Applicable product column
Molded with Cable

Source: PDF 35

Panel, male contacts6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
36

Source: PDF 36

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Maximum panel thickness
3 mm
Applicability and sources

Applicability

Applicable PDF pages
36

Source: PDF 36

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M16 series appearance reference

Series appearance reference · does not represent the individual pin positions and dimensions of each configuration.

Circular waterproof connectors

M16

Locking: threaded / quick-latch / bayonet / push-lock
Termination: wire soldering / overmolded with cable
Mounting: front panel / in-line

Series-level options; not every order number includes all of them.

Source: PDF 37 (printed page 34) · PDF 38 (printed page 35) · PDF 40 (printed page 37)

Expand 3 catalog parameter groups
Series brochure page material2 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 37

Applies only to the product row and pin count on that page; not inherited across series

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 37

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 37

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Front-mount panel6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
38

Source: PDF 38

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Maximum panel thickness
3 mm
Applicability and sources

Applicability

Applicable PDF pages
38

Source: PDF 38

Assembly cable-to-cable6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
40

Source: PDF 40

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Cable outer diameter, max
8.5 mm
Applicability and sources

Applicability

Applicable PDF pages
40

Source: PDF 40

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M19 series appearance reference

Series appearance reference · does not represent the individual pin positions and dimensions of each configuration.

Circular waterproof connectors

M19

Locking: threaded / quick-latch / bayonet / push-lock
Termination: wire soldering / overmolded with cable
Mounting: front panel / flange / in-line

Series-level options; not every order number includes all of them.

Source: PDF 55 (printed page 51) · PDF 57 (printed page 53) · PDF 59 (printed page 55) · PDF 63 (printed page 59) · PDF 65 (printed page 60)

  • Female contacts 2–6 pin on PDF 59/printed 55 are rated 250V; male contacts 2–4 pin 600V and 5–6 pin 300V on PDF 65/printed 60; they must not override each other.
Expand 4 catalog parameter groups
Series brochure page material2 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

Applies only to the product row and pin count on that page; not inherited across series

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Front-mount/flange6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Maximum panel thickness
3 mm
Applicability and sources

Applicability

Applicable PDF pages
57 · 63

Source: PDF 57 · PDF 63

Assembly cable-to-cable6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Cable outer diameter, min
6 mm
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Cable outer diameter, max
10 mm
Applicability and sources

Applicability

Applicable PDF pages
59 · 65

Source: PDF 59 · PDF 65

Advertised as IP683 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

Applies only to the product row and pin count on that page; not inherited across series

  • The series specification page states IP67; IP68 lacks test conditions, so the SKU rating cannot be upgraded.
Catalog protection rating
IP68
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

  • The series specification page states IP67; IP68 lacks test conditions, so the SKU rating cannot be upgraded.
IP test water depth
Not published · verify
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

  • The series specification page states IP67; IP68 lacks test conditions, so the SKU rating cannot be upgraded.
IP test duration
Not published · verify
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 55

  • The series specification page states IP67; IP68 lacks test conditions, so the SKU rating cannot be upgraded.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M22

For outline and mounting dimensions, see the corresponding original catalog page.

Circular waterproof connectors

M22

Locking: threaded
Termination: wire soldering/screw-clamp wiring (page heading is options)
Mounting: in-line

Series-level options; not every order number includes all of them.

Source: PDF 69 (printed page 64)

Expand 1 set of catalog parameters
Assembly threaded6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
69

Source: PDF 69

Applies only to the product row and pin count on that page; not inherited across series

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Cable outer diameter, max
10 mm
Applicability and sources

Applicability

Applicable PDF pages
69

Source: PDF 69

  • Solder / screw termination is the termination option in the page title; whether a given pin count has screw terminals must be confirmed against controlled drawings.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M25 series appearance reference

Series appearance reference · specific configurations to be confirmed per drawings.

Circular waterproof connectors

M25

Locking: threaded / push-lock
Termination: wire soldering / overmolded with cable
Mounting: flange / front panel / in-line

Series-level options; not every order number includes all of them.

Source: PDF 74 (printed page 69) · PDF 75 (printed page 70) · PDF 76 (printed page 70) · PDF 77 (printed page 71) · PDF 81 (printed page 75)

  • PDF 75 and 76 printed pages are both marked 70 but correspond to female/male contacts; some voltages differ (600V/300V), so the PDF page number and column must be retained.
Expand 3 catalog parameter groups
Series brochure page material2 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 74

Applies only to the product row and pin count on that page; not inherited across series

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 74

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series promotional material; does not represent every configuration
Directly applicable to the specific ordering number
No

Source: PDF 74

  • The marketing page provides no nylon grade, plating thickness, or per-SKU material declarations.
Flange / panel6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Maximum panel thickness
3 mm
Applicability and sources

Applicability

Applicable PDF pages
75 · 76 · 77

Source: PDF 75 · PDF 76 · PDF 77

Molded with cable6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
81

Source: PDF 81

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
81

Source: PDF 81

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M29 push-lock screw-clamp heavy duty catalog original image

Original catalog image · M29 push-lock screw-clamp heavy duty. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Circular waterproof connectors

M29

Locking: threaded / push-lock
Termination: screw-clamp wiring / wire soldering/screw-lock wiring / overmolded with cable
Mounting: front panel / rear panel / in-line straight / in-line 90-degree

Series-level options; not every order number includes all of them.

Source: PDF 91 (printed page 85) · PDF 92 (printed page 86) · PDF 93 (printed page 87) · PDF 94 (printed page 88) · PDF 95 (printed page 89) · PDF 96 (printed page 90) · PDF 97 (printed page 91) · PDF 98 (printed page 92) · PDF 99 (printed page 93)

  • PDF 91–99 do not specify material, copper alloy grade of contacts, nickel/gold plating system or plating thickness; phosphor bronze/nickel-gold cannot be inherited from model colors, photos or promotional pages of other series.
  • M29 heavy duty pages with different genders/housings show inconsistent 45A and 50A ratings: PDF96 is 45A, PDF91–95 are 50A; do not uniformly apply 50A; mating rating to be verified.
Expand 6 catalog parameter groups
50A heavy-duty screw-clamp termination, 2/3/4 contacts (PDF 91–95)10 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

Applies only to the product row and pin count on that page; not inherited across series

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Cable outer diameter, min
10 mm
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Catalog actual pin count
2 · 3 · 4
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Rated current
50 A
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Rated voltage
600 V
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
Contact diameter
4 mm
Applicability and sources

Applicability

Applicable PDF pages
91 · 92 · 93 · 94 · 95

Source: PDF 91 · PDF 92 · PDF 93 · PDF 94 · PDF 95

  • This group's actual SKUs list only 2/3/4 pins; there is no evidence of a 5-pin 50A version.
  • The female housing with female contacts on PDF 96 is explicitly 45A, differing from this group's 50A; the allowable current after mating must be verified and is not unified to 50A by series or part-number prefix.
45A heavy-duty female housing, female contacts, screw-clamp termination, 2/3/4 contacts (PDF 96)10 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
96

Source: PDF 96

Applies only to the product row and pin count on that page; not inherited across series

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Cable outer diameter, min
10 mm
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Catalog actual pin count
2 · 3 · 4
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Rated current
45 A
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Rated voltage
600 V
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Contact diameter
4 mm
Applicability and sources

Applicability

Applicable PDF pages
96

Source: PDF 96

  • The 2/3/4-pin rating tables on PDF 96/printed 90 are all 45A, 600V; although the actual part numbers start with 500, they are not changed to 50A on that basis.
  • The page note matches printed page 85 (PDF page 91), while that mating page is 50 A; the overall mated current rating is to be verified.
Multi-pin panel6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
97

Source: PDF 97

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Minimum panel thickness
1 mm
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Maximum panel thickness
5 mm
Applicability and sources

Applicability

Applicable PDF pages
97

Source: PDF 97

Multi-contact assembled5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Field assembly

Source: PDF 98 · PDF 99

Multi-contact overmolded5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

Cable outer diameter, max
17 mm
Applicability and sources

Applicability

Applicable PDF pages
98 · 99
Applicable product column
Molded with Cable

Source: PDF 98 · PDF 99

5 contacts5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

Applies only to the product row and pin count on that page; not inherited across series

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Contact count
5
Applicability and sources

Applicability

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Rated current
20 A
Applicability and sources

Applicability

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Maximum conductor cross section
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Conductor-to-wire-gauge relationship
Upper limit
Applicability and sources

Applicability

Applicable PDF pages
97 · 98 · 99
Contact count
5

Source: PDF 97 · PDF 98 · PDF 99

  • Solder/Screw in the assembly/panel column are only optional catalog termination descriptions, insufficient to mark every multi-contact SKU as definite screw wiring.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M45 screw-clamp wire original catalog image

Original catalog image · M45 screw-clamp. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

High-current connector

M45

Locking: threaded
Termination: screw-lock wiring

Series-level options; not every order number includes all of them.

Source: PDF 100 (printed page 94)

  • The part number table lists 2/3/4 pins; the rating table lists 3/4/5 pins. Do not force alignment by column position.
Expand 2 catalog parameter groups
Shared environment for this page5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
100

Source: PDF 100

Applies only to the product row and pin count on that page; not inherited across series

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
100

Source: PDF 100

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
100

Source: PDF 100

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Catalog protection rating
IP67/IP68
Applicability and sources

Applicability

Applicable PDF pages
100

Source: PDF 100

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
100

Source: PDF 100

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Cable outer diameter, max
25 mm
Applicability and sources

Applicability

Applicable PDF pages
100

Source: PDF 100

  • IP68 without depth/duration/mating state; not equivalent to IP69K.
Contact count listed in the rating table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Parameter table recorded; ordering number correspondence to be verified
Directly applicable to the specific ordering number
No

Source: PDF 100

Applies only to the product row and pin count on that page; not inherited across series

Ratings by pin count
Contact countCurrent (A)Voltage (V)Maximum conductor cross section (mm²)
38025010
48025010
5802506
Applicability and sources

Applicability

Documentation scope
Parameter table recorded; ordering number correspondence to be verified
Directly applicable to the specific ordering number
No

Source: PDF 100

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LA20

For outline and mounting dimensions, see the corresponding original catalog page.

Industrial waterproof connectors

LA20

Mounting: assembly plug / panel

Series-level options; not every order number includes all of them.

Source: PDF 101 (printed page 95)

Expand 1 set of catalog parameters
Assembly plug7 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
101

Source: PDF 101

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Cable outer diameter, min
8 mm
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Cable outer diameter, max
13 mm
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Contact positions and terminal diameter
Contact countDiameter (mm)
2 · 3 · 42.7
5 · 6 · 7 · 81.8
9 · 10 · 121
Applicability and sources

Applicability

Applicable PDF pages
101

Source: PDF 101

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LT20 series appearance reference

Series appearance reference · does not represent the individual pin positions and dimensions of each configuration.

Industrial waterproof connectors

LT20

Mounting: assembly plug / panel

Series-level options; not every order number includes all of them.

Source: PDF 103 (printed page 97)

Expand 1 set of catalog parameters
Assembly plug7 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
103

Source: PDF 103

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Cable outer diameter, min
8 mm
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Cable outer diameter, max
13 mm
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Contact positions and terminal diameter
Contact countDiameter (mm)
2 · 3 · 42.7
5 · 6 · 7 · 81.8
9 · 10 · 121
Applicability and sources

Applicability

Applicable PDF pages
103

Source: PDF 103

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
RJ45-M19 front-panel mount catalog source image

Original catalog image · RJ45-M19 front-mount panel. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Network interface

RJ45-M19

Locking: threaded
Mounting: front panel with cable / front panel potted with cable / front panel 180-degree / front panel 90-degree / in-line

Series-level options; not every order number includes all of them.

Source: PDF 52 (printed page 48) · PDF 54 (printed page 50)

  • Network speed, CAT rating, shielding standard, and PoE ratings are not stated and cannot be added.
Expand 2 catalog parameter groups
PDF527 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
52

Source: PDF 52

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Confirm conductor AWG
24
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Cable outer diameter, max
8 mm
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

Maximum panel thickness
10 mm
Applicability and sources

Applicability

Applicable PDF pages
52

Source: PDF 52

PDF547 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
54

Source: PDF 54

Applies only to the product row and pin count on that page; not inherited across series

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Confirm conductor AWG
24
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Cable outer diameter, max
7 mm
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Maximum panel thickness
10 mm
Applicability and sources

Applicability

Applicable PDF pages
54

Source: PDF 54

  • The panel icon shows max 4.5 while the table shows max 10 mm; the conflict is retained. The LLT-M19-121701 and PDF52 differ in outer diameter.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
RJ45-M16 quick-clip assembly catalog source image

Original catalog image · RJ45-M16 quick-latch assembly. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Network interface

RJ45-M16

Locking: quick-latch
Termination: assembly / overmolded with cable

Series-level options; not every order number includes all of them.

Source: PDF 53 (printed page 49)

Expand 2 catalog parameter groups
Assembly6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Confirm conductor AWG
24
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Cable outer diameter, max
7 mm
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-131201

Source: PDF 53

Molded6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Confirm conductor AWG
24
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Cable outer diameter, max
7 mm
Applicability and sources

Applicability

Applicable order numbers
LLT-M16-133201

Source: PDF 53

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
L16 in-line catalog original image

Original catalog image · L16 inline. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Junction box / splitter

L16

Termination: screw-clamp wiring

Series-level options; not every order number includes all of them.

Source: PDF 106 (printed page 100) · PDF 107 (printed page 101)

Expand 3 catalog parameter groups
Environment4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
106 · 107

Source: PDF 106 · PDF 107

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
106 · 107

Source: PDF 106 · PDF 107

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
106 · 107

Source: PDF 106 · PDF 107

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
106 · 107

Source: PDF 106 · PDF 107

Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
106 · 107

Source: PDF 106 · PDF 107

Inline/T 2 or 3 pins4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
106
Applicable pin counts
2 · 3

Source: PDF 106

Applies only to the product row and pin count on that page; not inherited across series

  • A 4-contact SKU exists but has no column in the ratings table.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
106
Applicable pin counts
2 · 3

Source: PDF 106

  • A 4-contact SKU exists but has no column in the ratings table.
Rated current
15 A
Applicability and sources

Applicability

Applicable PDF pages
106
Applicable pin counts
2 · 3

Source: PDF 106

  • A 4-contact SKU exists but has no column in the ratings table.
Maximum conductor cross section
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
106
Applicable pin counts
2 · 3

Source: PDF 106

  • A 4-contact SKU exists but has no column in the ratings table.
Cable outer diameter options as stated in the original text
Max.5.5mm/7.5mm
Applicability and sources

Applicability

Applicable PDF pages
106
Applicable pin counts
2 · 3

Source: PDF 106

  • A 4-contact SKU exists but has no column in the ratings table.
Branch, 2/3 contacts4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
107

Source: PDF 107

Applies only to the product row and pin count on that page; not inherited across series

  • This row states panel thickness in both Chinese and English; although it may be a misplaced cable outer diameter, it is not rewritten as OD.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
107

Source: PDF 107

  • This row states panel thickness in both Chinese and English; although it may be a misplaced cable outer diameter, it is not rewritten as OD.
Rated current
15 A
Applicability and sources

Applicability

Applicable PDF pages
107

Source: PDF 107

  • This row states panel thickness in both Chinese and English; although it may be a misplaced cable outer diameter, it is not rewritten as OD.
Maximum conductor cross section
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
107

Source: PDF 107

  • This row states panel thickness in both Chinese and English; although it may be a misplaced cable outer diameter, it is not rewritten as OD.
Panel thickness as stated in the original text
5.5mm–7.5mm
Applicability and sources

Applicability

Applicable PDF pages
107

Source: PDF 107

  • This row states panel thickness in both Chinese and English; although it may be a misplaced cable outer diameter, it is not rewritten as OD.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
L20 in-line catalog original image

Original catalog image · L20 inline. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Junction box / splitter

L20

Termination: screw-clamp wiring
Mounting: assembly / panel / overmolded with cable

Series-level options; not every order number includes all of them.

Source: PDF 108 (printed page 102) · PDF 109 (printed page 103) · PDF 110 (printed page 104)

Expand 3 catalog parameter groups
Shared environment4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
108 · 109 · 110

Source: PDF 108 · PDF 109 · PDF 110

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
108 · 109 · 110

Source: PDF 108 · PDF 109 · PDF 110

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
108 · 109 · 110

Source: PDF 108 · PDF 109 · PDF 110

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
108 · 109 · 110

Source: PDF 108 · PDF 109 · PDF 110

Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
108 · 109 · 110

Source: PDF 108 · PDF 109 · PDF 110

Inline/T/X4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
108

Source: PDF 108

Applies only to the product row and pin count on that page; not inherited across series

  • X four-way column repeats the T three-way part numbers; X-type SKUs cannot be constructed.
Current by pin count
2 pins
20 A
3 pins
20 A
4 contacts
15 A
Applicability and sources

Applicability

Applicable PDF pages
108

Source: PDF 108

  • X four-way column repeats the T three-way part numbers; X-type SKUs cannot be constructed.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
108

Source: PDF 108

  • X four-way column repeats the T three-way part numbers; X-type SKUs cannot be constructed.
Conductor cross-section limits by pin count
2 pins
1.5 mm²
3 pins
1.5 mm²
4 contacts
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
108

Source: PDF 108

  • X four-way column repeats the T three-way part numbers; X-type SKUs cannot be constructed.
Cable outer diameter options as stated in the original text
Max.5.5mm/7.5mm/10.0mm
Applicability and sources

Applicability

Applicable PDF pages
108

Source: PDF 108

  • X four-way column repeats the T three-way part numbers; X-type SKUs cannot be constructed.
Panel / overmolded / Y5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

Applies only to the product row and pin count on that page; not inherited across series

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Current by pin count
2 pins
20 A
3 pins
20 A
4 contacts
15 A
Applicability and sources

Applicability

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Conductor cross-section limits by pin count
2 pins
1 mm²
3 pins
1 mm²
4 contacts
0.75 mm²
Applicability and sources

Applicability

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Cable outer diameter, min
5.5 mm
Applicability and sources

Applicability

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Cable outer diameter, max
10 mm
Applicability and sources

Applicability

Applicable PDF pages
109 · 110

Source: PDF 109 · PDF 110

  • The 4-pin column on PDF 110 repeats the 3-pin part numbers; the conflicting record is quarantined.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
L25 in-line screw-clamp wiring catalog original image

Original catalog image · L25 inline screw-clamp. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Junction box / splitter

L25

Termination: screw-clamp wiring / solder-free, screw-free quick connect

Series-level options; not every order number includes all of them.

Source: PDF 111 (printed page 105)

Expand 2 catalog parameter groups
Environment common to this page6 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
111

Source: PDF 111

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Cable outer diameter, min
10 mm
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Cable outer diameter, max
16 mm
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

Corresponding pin-count rating table1 parameter · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
111

Source: PDF 111

Applies only to the product row and pin count on that page; not inherited across series

  • The 5-contact SKU column explicitly exists, but the ratings table lacks a 5-contact column; 20A cannot be inferred from the 20005 part-number segment.
Ratings by pin count
Contact countCurrent (A)Voltage (V)Maximum conductor cross section (mm²)
2352504
3352502.5
4202501.5
5Not published · verifyNot published · verifyNot published · verify
Applicability and sources

Applicability

Applicable PDF pages
111

Source: PDF 111

  • The 5-contact SKU column explicitly exists, but the ratings table lacks a 5-contact column; 20A cannot be inferred from the 20005 part-number segment.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M15 assembly catalog original image

Original catalog image · M15 assembly. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Circular waterproof connectors

M15

Locking: threaded
Termination: wire soldering / overmolded with cable

Series-level options; not every order number includes all of them.

Source: PDF 112 (printed page 106) · PDF 113 (printed page 107)

Expand 2 catalog parameter groups
Circular connectors10 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
112

Source: PDF 112

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Catalog protection rating
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Cable outer diameter, min
3.5 mm
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Cable outer diameter, max
8.5 mm
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Rated current
15 A
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Maximum conductor cross section
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

IP rating as listed per product
Assembly
IP67
Molded
IP65
Applicability and sources

Applicability

Applicable PDF pages
112

Source: PDF 112

Distributor8 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
113

Source: PDF 113

Applies only to the product row and pin count on that page; not inherited across series

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Rated current
15 A
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Conductor cross-section limits by pin count
2 pins
1 mm²
3 pins
0.75 mm²
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Cable outer diameter, max
8 mm
Applicability and sources

Applicability

Applicable PDF pages
113

Source: PDF 113

  • Chinese threaded contradicts English Push Lock; locking method to be confirmed. Some SKU current code 050 differs from the table's 15A; the table value is used and recorded.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Original catalog image of M16 quick-connect distributor

Original catalog image · M16 quick-connect distributor. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Distributor

M16 Distributor

Locking: threaded / quick-connect
Termination: overmolded with cable (soldered)

Series-level options; not every order number includes all of them.

Source: PDF 114 (printed page 108) · PDF 115 (printed page 109)

Expand 1 set of catalog parameters
Distributor8 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

Applies only to the product row and pin count on that page; not inherited across series

  • Part number 150 does not confirm 15A; the rating table is 10A.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Mechanical mating life
500 cycles
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Rated voltage
250 V
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Rated current
10 A
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Conductor cross-section limits by pin count
2 pins
1 mm²
3 pins
0.75 mm²
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Cable outer diameter, max
8 mm
Applicability and sources

Applicability

Applicable PDF pages
114 · 115

Source: PDF 114 · PDF 115

  • Part number 150 does not confirm 15A; the rating table is 10A.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Y/T

For outline and mounting dimensions, see the corresponding original catalog page.

Branch harnesses and assembled splitters

Y/T

Series-level options; not every order number includes all of them.

Source: PDF 116 (printed page 110) · PDF 117 (printed page 111) · PDF 118 (printed page 112) · PDF 119 (printed page 113) · PDF 120 (printed page 114)

Expand 17 sets of catalog parameters
Y/T molded4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
116 · 117 · 118 · 119

Source: PDF 116 · PDF 117 · PDF 118 · PDF 119

Applies only to the product row and pin count on that page; not inherited across series

  • Main/branch wire gauges and OD must be recorded separately; this group lists no current/voltage; do not infer rated current from part number 100/200.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
116 · 117 · 118 · 119

Source: PDF 116 · PDF 117 · PDF 118 · PDF 119

  • Main/branch wire gauges and OD must be recorded separately; this group lists no current/voltage; do not infer rated current from part number 100/200.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
116 · 117 · 118 · 119

Source: PDF 116 · PDF 117 · PDF 118 · PDF 119

  • Main/branch wire gauges and OD must be recorded separately; this group lists no current/voltage; do not infer rated current from part number 100/200.
Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable PDF pages
116 · 117 · 118 · 119

Source: PDF 116 · PDF 117 · PDF 118 · PDF 119

  • Main/branch wire gauges and OD must be recorded separately; this group lists no current/voltage; do not infer rated current from part number 100/200.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable PDF pages
116 · 117 · 118 · 119

Source: PDF 116 · PDF 117 · PDF 118 · PDF 119

  • Main/branch wire gauges and OD must be recorded separately; this group lists no current/voltage; do not infer rated current from part number 100/200.
Assembly M16-T/M19-T/Y5 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
120

Source: PDF 120

Applies only to the product row and pin count on that page; not inherited across series

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
120

Source: PDF 120

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
120

Source: PDF 120

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Catalog protection rating
IP65
Applicability and sources

Applicability

Applicable PDF pages
120

Source: PDF 120

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Mechanical mating life
3000 cycles
Applicability and sources

Applicability

Applicable PDF pages
120

Source: PDF 120

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Ratings by product type
StructureCurrent (A)Voltage (V)Maximum conductor cross section (mm²)
M16-T102501.5
M19-T/Y202502.5
Applicability and sources

Applicability

Applicable PDF pages
120

Source: PDF 120

  • The M19 title column uses SKUs with a D19 prefix; kept as in the original text, not renumbered.
Y small4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
116
Applicable product column
Y small
Directly applicable to the specific ordering number
No

Source: PDF 116

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y small
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch conductor cross-section upper limit
0.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y small
Directly applicable to the specific ordering number
No

Source: PDF 116

Main cable outer diameter max
9 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y small
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch cable outer diameter upper limit
7.5 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y small
Directly applicable to the specific ordering number
No

Source: PDF 116

Y medium4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
116
Applicable product column
Y medium
Directly applicable to the specific ordering number
No

Source: PDF 116

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y medium
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch conductor cross-section upper limit
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y medium
Directly applicable to the specific ordering number
No

Source: PDF 116

Main cable outer diameter max
9 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y medium
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch cable outer diameter upper limit
8 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y medium
Directly applicable to the specific ordering number
No

Source: PDF 116

Y standard4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
116
Applicable product column
Y standard
Directly applicable to the specific ordering number
No

Source: PDF 116

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y standard
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch conductor cross-section upper limit
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y standard
Directly applicable to the specific ordering number
No

Source: PDF 116

Main cable outer diameter max
9 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y standard
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch cable outer diameter upper limit
8 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y standard
Directly applicable to the specific ordering number
No

Source: PDF 116

Y enlarged4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
116
Applicable product column
Y enlarged
Directly applicable to the specific ordering number
No

Source: PDF 116

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
4 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y enlarged
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch conductor cross-section upper limit
0.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y enlarged
Directly applicable to the specific ordering number
No

Source: PDF 116

Main cable outer diameter max
16 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y enlarged
Directly applicable to the specific ordering number
No

Source: PDF 116

Branch cable outer diameter upper limit
13 mm
Applicability and sources

Applicability

Applicable PDF pages
116
Applicable product column
Y enlarged
Directly applicable to the specific ordering number
No

Source: PDF 116

Y pre-branched cable4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
117
Applicable product column
Y pre-branched cable
Directly applicable to the specific ordering number
No

Source: PDF 117

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
4 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y pre-branched cable
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch conductor cross-section upper limit
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y pre-branched cable
Directly applicable to the specific ordering number
No

Source: PDF 117

Main cable outer diameter max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y pre-branched cable
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch cable outer diameter upper limit
12 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y pre-branched cable
Directly applicable to the specific ordering number
No

Source: PDF 117

Y gun-type S4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
117
Applicable product column
Y gun-type S
Directly applicable to the specific ordering number
No

Source: PDF 117

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type S
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch conductor cross-section upper limit
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type S
Directly applicable to the specific ordering number
No

Source: PDF 117

Main cable outer diameter max
11 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type S
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch cable outer diameter upper limit
9 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type S
Directly applicable to the specific ordering number
No

Source: PDF 117

Y gun-type L4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
117
Applicable product column
Y gun-type L
Directly applicable to the specific ordering number
No

Source: PDF 117

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
6 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type L
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch conductor cross-section upper limit
4 mm²
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type L
Directly applicable to the specific ordering number
No

Source: PDF 117

Main cable outer diameter max
19 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type L
Directly applicable to the specific ordering number
No

Source: PDF 117

Branch cable outer diameter upper limit
16 mm
Applicability and sources

Applicability

Applicable PDF pages
117
Applicable product column
Y gun-type L
Directly applicable to the specific ordering number
No

Source: PDF 117

T standard 14 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
119
Applicable product column
T standard 1
Directly applicable to the specific ordering number
No

Source: PDF 119

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 1
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch conductor cross-section upper limit
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 1
Directly applicable to the specific ordering number
No

Source: PDF 119

Main cable outer diameter max
11 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 1
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch cable outer diameter upper limit
10 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 1
Directly applicable to the specific ordering number
No

Source: PDF 119

T standard 24 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
119
Applicable product column
T standard 2
Directly applicable to the specific ordering number
No

Source: PDF 119

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 2
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch conductor cross-section upper limit
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 2
Directly applicable to the specific ordering number
No

Source: PDF 119

Main cable outer diameter max
8.5 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 2
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch cable outer diameter upper limit
8.5 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T standard 2
Directly applicable to the specific ordering number
No

Source: PDF 119

T medium4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
119
Applicable product column
T medium
Directly applicable to the specific ordering number
No

Source: PDF 119

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T medium
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch conductor cross-section upper limit
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T medium
Directly applicable to the specific ordering number
No

Source: PDF 119

Main cable outer diameter max
12 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T medium
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch cable outer diameter upper limit
11 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T medium
Directly applicable to the specific ordering number
No

Source: PDF 119

T large4 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
119
Applicable product column
T large
Directly applicable to the specific ordering number
No

Source: PDF 119

Applies only to the product row and pin count on that page; not inherited across series

Main conductor cross-section max
4 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T large
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch conductor cross-section upper limit
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T large
Directly applicable to the specific ordering number
No

Source: PDF 119

Main cable outer diameter max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T large
Directly applicable to the specific ordering number
No

Source: PDF 119

Branch cable outer diameter upper limit
12 mm
Applicability and sources

Applicability

Applicable PDF pages
119
Applicable product column
T large
Directly applicable to the specific ordering number
No

Source: PDF 119

M12-T2 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
118
Applicable product column
M12-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Applies only to the product row and pin count on that page; not inherited across series

Maximum conductor cross section
1 mm²
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M12-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Cable outer diameter, max
7.8 mm
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M12-T
Directly applicable to the specific ordering number
No

Source: PDF 118

M16-T2 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
118
Applicable product column
M16-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Applies only to the product row and pin count on that page; not inherited across series

Maximum conductor cross section
1.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M16-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Cable outer diameter, max
9 mm
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M16-T
Directly applicable to the specific ordering number
No

Source: PDF 118

M19-T2 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
118
Applicable product column
M19-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Applies only to the product row and pin count on that page; not inherited across series

Maximum conductor cross section
2.5 mm²
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M19-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Cable outer diameter, max
10 mm
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M19-T
Directly applicable to the specific ordering number
No

Source: PDF 118

M25-T2 parameters · applicable per source scope

Applicability of this parameter set

Applicable PDF pages
118
Applicable product column
M25-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Applies only to the product row and pin count on that page; not inherited across series

Maximum conductor cross section
4 mm²
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M25-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Cable outer diameter, max
12 mm
Applicability and sources

Applicability

Applicable PDF pages
118
Applicable product column
M25-T
Directly applicable to the specific ordering number
No

Source: PDF 118

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M29 photovoltaic catalog original image

Original catalog image · M29 PV. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

PV connector

M29-PV

Mounting: rear panel / in-line assembly

Series-level options; not every order number includes all of them.

Source: PDF 121 (printed page 115)

  • Chinese states push-lock/screw clamp, English states Thread/Solder; both locking and termination conflict, so neither can be silently chosen.
Expand 1 set of catalog parameters
Electrical environment9 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
121

Source: PDF 121

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Cable outer diameter, min
10 mm
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Rated voltage
600 V
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Rated current
30 A
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Contact diameter
3 mm
Applicability and sources

Applicability

Applicable PDF pages
121

Source: PDF 121

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
M35 PV original catalog image

Original catalog image · M35 PV. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

PV connector

M35-PV

Mounting: rear panel / in-line assembly

Series-level options; not every order number includes all of them.

Source: PDF 122 (printed page 116)

  • Chinese states push-lock/screw clamp, English states Thread/Solder; both locking and termination conflict, so neither can be silently chosen.
Expand 1 set of catalog parameters
Electrical environment9 parameters · applicable within documented scope

Applicability of this parameter set

Applicable PDF pages
122

Source: PDF 122

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Mechanical mating life
1500 cycles
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Cable outer diameter, min
10 mm
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Cable outer diameter, max
15 mm
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Rated voltage
600 V
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Rated current
20 A
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Contact diameter
2 mm
Applicability and sources

Applicability

Applicable PDF pages
122

Source: PDF 122

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LPEV 8.0 energy storage connector, original catalog image

Original catalog image · LPEV 8.0 energy storage connector. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Energy storage connector

LPEV

Locking: push-lock
Mounting: panel receptacle / 90-degree plug

Series-level options; not every order number includes all of them.

Source: PDF 123 (printed page 117)

Expand 2 catalog parameter groups
Type 6.09 parameters · applicable within documented scope

Applicability of this parameter set

Applicable product column
1 · 2

Source: PDF 123

Applies only to the product row and pin count on that page; not inherited across series

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Cable outer diameter, min
8 mm
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Cable outer diameter, max
12 mm
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Rated voltage
1500 V
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Current options
100 · 120 · 150 A
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Conductor cross section options
16 · 25 · 35 mm²
Applicability and sources

Applicability

Applicable product column
1 · 2

Source: PDF 123

  • Ratings and conductors are options within the column; the per-SKU correspondence is not fully specified.
Type 8.09 parameters · applicable within documented scope

Applicability of this parameter set

Applicable product column
3 · 4

Source: PDF 123

Applies only to the product row and pin count on that page; not inherited across series

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Catalog protection rating
IP67
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Cable outer diameter, min
12 mm
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Cable outer diameter, max
18 mm
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Rated voltage
1500 V
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Current options
200 · 250 · 300 A
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Conductor cross section options
35 · 50 · 75 mm²
Applicability and sources

Applicability

Applicable product column
3 · 4

Source: PDF 123

  • Rated current cannot be automatically confirmed from part numbers 200/250; there is no AC/DC system designation.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LPL-300

For outline and mounting dimensions, see the corresponding original catalog page.

High-current / rectangular connectors for new energy

LPL-300

Locking: push-pull
Termination: plug crimp / receptacle threaded connection/copper busbar/crimp

Series-level options; not every order number includes all of them.

Source: PDF 125

  • Temperature, mechanical life, and AC/DC voltage conflict across different columns on the same page; they cannot be combined into a higher rating.
Expand 3 catalog parameter groups
Main performance/electrical table22 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Applies only to the product row and pin count on that page; not inherited across series

Housing material
Anodized / nickel-plated aluminum alloy housing
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Insulator material
PBT
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Seal material
Silicone rubber
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Contact plating
Silver-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Contact resistance (original table)
0.2 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

  • The original table does not state an upper-limit comparison symbol; it is not used to filter as a guaranteed upper limit.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Rated voltage
600 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Rated voltage system
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Withstand-voltage type
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

IP statement mating/installation conditions
Receptacle mounting end and mating interface; the mounting portion is guaranteed by the customer
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Vibration frequency upper limit
2000 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Vibration acceleration
196 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Shock acceleration as stated in the original text
980m²/s (unit in the original appears abnormal)
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Operating temperature lower limit
-55 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Operating temperature upper limit
90 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Relative humidity
95 %
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Relative humidity test temperature
40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

English Spec box (conflicts with key performance data)11 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Operating temperature upper limit
125 °C
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Rated current
300 A
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Rated voltage
1000 V
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Rated voltage system
DC
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Withstand-voltage type
DC
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Catalog protection rating
IP67 & IP2X
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Minimum mechanical life
100 cycles
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

High-voltage interlock
Yes
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Automatic secondary latch
Yes
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 125

Conductor-to-current table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Applies only to the product row and pin count on that page; not inherited across series

Conductor-to-current table
Rated current (A)Conductor cross section (mm²)
8025
15035
20050
30070
Applicability and sources

Applicability

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 125

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LPL-500

For outline and mounting dimensions, see the corresponding original catalog page.

High-current / rectangular connectors for new energy

LPL-500

Locking: push-pull
Termination: plug crimp / receptacle threaded connection/copper busbar/crimp

Series-level options; not every order number includes all of them.

Source: PDF 128

  • Temperature, mechanical life, and AC/DC voltage conflict across different columns on the same page; they cannot be combined into a higher rating.
Expand 3 catalog parameter groups
Main performance/electrical table22 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Applies only to the product row and pin count on that page; not inherited across series

Housing material
Anodized / nickel-plated aluminum alloy housing
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Insulator material
PBT
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Seal material
Silicone rubber
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Contact plating
Silver-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Contact resistance (original table)
0.2 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

  • The original table does not state an upper-limit comparison symbol; it is not used to filter as a guaranteed upper limit.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Rated voltage
600 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Rated voltage system
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Withstand-voltage type
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

IP statement mating/installation conditions
Receptacle mounting end and mating interface; the mounting portion is guaranteed by the customer
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Vibration frequency upper limit
2000 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Vibration acceleration
196 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Shock acceleration as stated in the original text
980m²/s (unit in the original appears abnormal)
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Operating temperature lower limit
-55 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Operating temperature upper limit
90 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Relative humidity
95 %
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Relative humidity test temperature
40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

English Spec box (conflicts with key performance data)11 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Applies only to the product row and pin count on that page; not inherited across series

Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Operating temperature upper limit
125 °C
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Rated current
300 A
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Rated voltage
1000 V
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Rated voltage system
DC
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Withstand-voltage type
DC
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Catalog protection rating
IP67 & IP2X
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Minimum mechanical life
100 cycles
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

High-voltage interlock
Yes
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Automatic secondary latch
Yes
Applicability and sources

Applicability

Documentation scope
Conflicting series documentation; requires separate confirmation
Directly applicable to the specific ordering number
No

Source: PDF 128

Conductor-to-current table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Applies only to the product row and pin count on that page; not inherited across series

Conductor-to-current table
Rated current (A)Conductor cross section (mm²)
30070
40090
500120
Applicability and sources

Applicability

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 128

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LPLE

For outline and mounting dimensions, see the corresponding original catalog page.

High-current / rectangular connectors for new energy

LPLE

Locking: push-pull
Termination: plug crimp / receptacle threaded connection/copper busbar/crimp

Series-level options; not every order number includes all of them.

Source: PDF 130

Expand 2 catalog parameter groups
Main performance/electrical table22 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Applies only to the product row and pin count on that page; not inherited across series

Housing material
Nylon
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Insulator material
PBT
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Seal material
Silicone rubber
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Contact plating
Silver-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Contact resistance (original table)
0.2 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

  • The original table does not state an upper-limit comparison symbol; it is not used to filter as a guaranteed upper limit.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Rated voltage
600 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Rated voltage system
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Withstand-voltage type
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

IP statement mating/installation conditions
Receptacle mounting end and mating interface; the mounting portion is guaranteed by the customer
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Vibration frequency upper limit
2000 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Vibration acceleration
196 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Shock acceleration as stated in the original text
980m²/s (unit in the original appears abnormal)
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Operating temperature lower limit
-55 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Operating temperature upper limit
90 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Relative humidity
95 %
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Relative humidity test temperature
40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Conductor-to-current table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Applies only to the product row and pin count on that page; not inherited across series

Conductor-to-current table
Rated current (A)Conductor cross section (mm²)
8025
12035
15050
Applicability and sources

Applicability

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 130

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LUG

For outline and mounting dimensions, see the corresponding original catalog page.

High-current / rectangular connectors for new energy

LUG

Locking: push-pull
Termination: plug crimp / receptacle threaded connection/copper busbar/crimp

Series-level options; not every order number includes all of them.

Source: PDF 132

Expand 2 catalog parameter groups
Main performance/electrical table17 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Applies only to the product row and pin count on that page; not inherited across series

Housing material
Anodized aluminum alloy housing
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Insulator material
PBT
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Seal material
Silicone rubber
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Contact plating
Silver-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Contact resistance (original table)
0.2 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

  • The original table does not state an upper-limit comparison symbol; it is not used to filter as a guaranteed upper limit.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Rated voltage
600 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Rated voltage system
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Withstand-voltage type
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

IP statement mating/installation conditions
Receptacle mounting end and mating interface; the mounting portion is guaranteed by the customer
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Vibration frequency upper limit
2000 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Vibration acceleration
196 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Shock acceleration as stated in the original text
980m²/s (unit in the original appears abnormal)
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Conductor-to-current table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Applies only to the product row and pin count on that page; not inherited across series

Conductor-to-current table
Rated current (A)Conductor cross section (mm²)
8025
13035
18050
23070
Applicability and sources

Applicability

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 132

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LC08

For outline and mounting dimensions, see the corresponding original catalog page.

High-current / rectangular connectors for new energy

LC08

Locking: push-pull
Termination: plug crimp / receptacle threaded connection/copper busbar/crimp

Series-level options; not every order number includes all of them.

Source: PDF 134

  • The body text states a rated operating current of 15A, while the high-current table below shows 80/130A and Φ8.0, which is inconsistent with the 32-pin drawing; it cannot be used to match current for specific LC08 SKUs.
Expand 2 catalog parameter groups
Main performance/electrical table22 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Applies only to the product row and pin count on that page; not inherited across series

Housing material
PA66
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Insulator material
PBT
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Seal material
Silicone rubber
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Contact plating
Silver-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Contact resistance (original table)
0.2 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

  • The original table does not state an upper-limit comparison symbol; it is not used to filter as a guaranteed upper limit.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Rated voltage
600 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Rated voltage system
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Withstand voltage
2500 V
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Withstand-voltage type
AC
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Mechanical mating life
500 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

IP statement mating/installation conditions
Receptacle mounting end and mating interface; the mounting portion is guaranteed by the customer
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Vibration frequency upper limit
2000 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Vibration acceleration
196 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Shock acceleration as stated in the original text
980m²/s (unit in the original appears abnormal)
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Operating temperature lower limit
-55 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Operating temperature upper limit
90 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Relative humidity
95 %
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Relative humidity test temperature
40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Conductor-to-current table1 parameter · applicable per source scope

Applicability of this parameter set

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Applies only to the product row and pin count on that page; not inherited across series

Conductor-to-current table
Rated current (A)Conductor cross section (mm²)
8020
13035
Applicability and sources

Applicability

Documentation scope
Series parameter table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 134

Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LT63 metal circular, original catalog image

Original catalog image · LT63 metal circular. For identifying series appearance; verify pin positions and dimensions against the specific configuration.

Metal circular connector

LT63

Series-level options; not every order number includes all of them.

Source: PDF 136 (printed page 119)

Expand 1 set of catalog parameters
Main technical performance19 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

Applies only to the product row and pin count on that page; not inherited across series

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Housing material
Zinc alloy / aluminum alloy
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulator material
PA
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Flammability rating
UL94-V0
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact material
Copper alloy
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Mechanical mating life
200 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Rated current
13 A
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact resistance upper limit
3 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulation resistance test conditions
Room temperature
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
EMI shielding
80 dB
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Shielding test frequency
1 MHz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration frequency upper limit
500 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration acceleration
100 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 136

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
LT/LTHP

For outline and mounting dimensions, see the corresponding original catalog page.

Metal circular connector

LT/LTHP

Series-level options; not every order number includes all of them.

Source: PDF 137 (printed page 120)

Expand 1 set of catalog parameters
Main technical performance19 parameters · applicable per source scope

Applicability of this parameter set

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

Applies only to the product row and pin count on that page; not inherited across series

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Housing material
Zinc alloy / aluminum alloy
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulator material
PA
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Flammability rating
UL94-V0
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact material
Copper alloy
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact plating
Gold-plated
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Mechanical mating life
200 cycles
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Rated current
13 A
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Contact resistance upper limit
3 mΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulation resistance lower limit
5000 MΩ
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Insulation resistance test conditions
Room temperature
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
EMI shielding
80 dB
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Shielding test frequency
1 MHz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Operating temperature lower limit
-40 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Operating temperature upper limit
105 °C
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Salt spray test
48 h
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Catalog protection rating
IP67
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration frequency lower limit
10 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration frequency upper limit
500 Hz
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Vibration acceleration
100 m/s²
Applicability and sources

Applicability

Documentation scope
Series technical table; not yet mapped item by item to order numbers
Directly applicable to the specific ordering number
No

Source: PDF 137

  • No complete SKU list; SKUs are not generated by full permutation of the naming rule.
Series-level parameters and applicability rules

The fields below show the publication status at series level. For specific products that already have values, see the parameter groups above.

Applicable across the entire series
No
Electrical ratings
Use only the column for the corresponding SKU and the row for its contact count; do not inherit the series maximum or ratings from a different gender or mounting type.
Optional configurations
seriesOptions only represents the available configurations of the series; it cannot be automatically assigned to all SKUs.
Unpublished parameters
Unconfirmed values remain null; do not infer current, pin count, or conductor range from part-number digits.
Operating temperature lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Operating temperature upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Mechanical mating life
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Catalog protection rating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test water depth
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test duration
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test pressure
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP test temperature
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
IP statement mating/installation conditions
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Housing material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulator material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Seal material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact material
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact plating
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Contact resistance upper limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Insulation resistance lower limit
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand voltage
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Withstand-voltage type
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Rated voltage system
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Salt spray test
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Minimum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Maximum panel thickness
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, min
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Cable outer diameter, max
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.
Certification scope
Not published · verify
Applicability and sources

Applicability

No published value uniformly applicable across the series

Source: corresponding page not marked

  • Cannot be inherited across the entire series; see specific evidence in variants.

READ THE SCOPE

Every set of values has a corresponding range.

Within the same series, materials, temperature, ratings, and protection rating may vary with pin count, product column, or mounting structure. Expand “Applicability and source” next to a parameter to check the corresponding page; “not specified” means no unified value is given in the current materials.

Original values retained in groups

The correspondence between pin count, current and conductor size is listed group by group; values are not summed, and series maximums are not carried over.

Traceable documentation pages

PDF page numbers refer to the page order within the file; printed page numbers are also listed where available. Series promotional materials and specific datasheets are described separately.

Do not fabricate ordering numbers

For duplicate part numbers, conflicting values, or entries not yet mapped to an order number in the catalog, notes are retained; no fabricated configurations are generated.