120A female-contact flange connector

LP-32

High current. A steadier connection.

LP-32 connector structure display

Rendered from a manufacturer-provided model. Electrical and verification parameters follow the conditions noted on this page. 14

LP-32 · Design intent

High current and vibration validated in one scenario, designed for the actual working conditions of equipment connections.

The LP-32 uses a female-contact flange structure for 120A loads and vibration conditions. Locking, contact retention, and mounting structure work together so the interface seats securely on the equipment.

120 ALoad current
6 gRandom vibration acceleration
≤25 °CTemperature rise

Manufacturer-provided verification information: 120 A load, 6 g random vibration test, temperature rise not exceeding 25 ℃. Here, 25 ℃ is a temperature rise, not an absolute temperature. Test spectrum, duration, environment, and report number are found in the official verification documents. 10

LP-32 original product waterproof theme display; see notes for performance applicability

LLT · Environmental protection

Water stays out.Connected inside.

From the mating interface and housing to the cable exit, check sealing point by point. Confirm the applicable solution per the protection rating, installation state and actual conditions of the specific model.

Confirm per specificationProtection rating and operating state

Protection applies only after correct mating, locking, and cable sealing are complete. The imagery is an environmental illustration, not footage of actual testing. Applicable conditions ↗

TAKE A CLOSER LOOK

From the mounting surface to every contact.

Drag to view the appearance; zoom in for details.

LP-32 female-contact flange connector, multi-angle views
01 / 24

Original model appearance render. The rotating-view demonstration does not imply that the product has a corresponding working rotation function; engineering conditions follow the technical information on this page.

LP-32 female-contact flange, built for equipment.

A closer look at the structure

Female-contact flange, facing the equipment.

The flange provides a clear mounting interface. Mating face outward, termination side inward. During installation, check mounting hole positions, panel, and cable routing together.

Shown is the mating face of a female-contact flange; final contacts and the complete part number follow the official drawings.
LP-32: from locking to contact retention.

A closer look at the structure

From locking to contact retention.

The blue push-lock, the external latch and the internal contacts together form the connection. Designed for vibration conditions, equipment mounting and cable support must also be included in validation.

Push-lock and threaded nut are different operating structures; random vibration results are not extended to all working conditions.

Technical information

Key parameters, with conditions stated clearly.

Load current
120 A
Mounting / contacts
Flange / female contacts
Random vibration acceleration
6 g
Test temperature rise
≤ 25 °C

The verification information above is provided by the manufacturer. Test duration, vibration spectrum, the definition of 6 g, ambient temperature, cable, and temperature measurement points must be confirmed together in the official report.

Back to device

State clearly where it connects.

Start from the connection position in the equipment to reduce selection errors based only on pin count and appearance.

Motors and power equipment

High-current flange interface on the equipment side

Selection focus: continuous load, vibration spectrum, contact retention, and harness supportView connection positions

Mobile equipment

Detachable power connections subject to mechanical vibration

Selection focus: mounting rigidity, temperature rise conditions, sealing, and maintenance frequencyView connection positions

Start with your equipment.

Tell us the load, wiring and installation space,
Determine the right connection solution together.

Contact engineer