Outdoor and greenhouse lighting
Choose your waterproof connector.

Power and signal, each with its own role.
Find the right connection for real working conditions.

LightingPV trackingHome energy storageMowing equipment
Outdoor and greenhouse lighting application illustration; confirm specific interfaces against equipment drawings
Outdoor and greenhouse lightingApplication concept image

Where the light reaches, connections stay in order.

From drivers and light strips to dimming lines, sorting out power, control and branches one by one. Choose waterproof connectors per connection point for easier installation and maintenance.

Driver power input

Connect the luminaire power cable to the driver. Cable-to-cable suits pre-assembled harnesses; panel interfaces make power module replacement easier.

Power off before replacing the driver; leave space for connector locking and cable bending.

Confirm these items first.

  • Is the input AC or DC? What is the maximum operating voltage?
  • What are the continuous current, startup surge and number of lights per branch for each fixture?
  • Is protective grounding required? What are the terminal and grounding-sequence requirements?

Ratings in the catalog that do not specify AC or DC cannot be taken directly as a commitment for either system. 3 pins do not automatically equal a confirmed L/N/PE assignment; verify against the drawings.

Catalog configuration reference · equipment conditions and mating side still to be verified
Part no. / structureContact countRated voltageRated current / contactMounting methodConductor cross section / cable outer diameterProtection / basis
LLT-M16-15003F1031
Push-lock · solder
3 pins250 V15 AWire-to-wire≤ 1.5 mm²
Cable Ø 3.5–8.5 mm
IP67
Catalog p. 40
LLT-M19-20003F3034
Push-lock · overmolded with cable
3 pins250 V20 AWire-to-wire≤ 2.5 mm²
Cable Ø 3.5–12 mm
IP65
Catalog p. 60
LLT-M25-35003F1031
Push-lock · solder
3 pins600 V35 AWire-to-wire≤ 4 mm²
Cable Ø 3.5–13 mm
IP67
Catalog p. 79

Ratings are listed per the corresponding catalog configuration; unstated AC/DC system, wiring order, and protocol require confirmation. The "≤" conductor value is the published upper limit, and the cable outer diameter must fall within the sealing accommodation range.

Driver to light strip

Deliver the driver output to the light strip. First verify output voltage and current, then confirm polarity, extension distance, and interface location.

Connect the light strip before power-on per equipment requirements; when replacing, identify polarity and prevent mis-mating.

Confirm these items first.

  • What are the driver's maximum output voltage and open-circuit voltage?
  • Constant-current or constant-voltage power supply? How many outputs?
  • What are the extension cable length, conductor cross section and allowable voltage drop?

Low-voltage light strips and high-voltage constant-current light strips cannot share default selection conditions. Waterproof rating cannot replace a wet-area electrical safety assessment.

Catalog configuration reference · equipment conditions and mating side still to be verified
Part no. / structureContact countRated voltageRated current / contactMounting methodConductor cross section / cable outer diameterProtection / basis
LLT-M12-10002F1051
Threaded · soldered wire
2 pins110 V10 AWire-to-wire≤ 1 mm²
Cable Ø 3.5–6.1 mm
Not listed
Catalog p. 20
LLT-M16-15002F1031
Push-lock · solder
2 pins250 V15 AWire-to-wire≤ 1.5 mm²
Cable Ø 3.5–8.5 mm
IP67
Catalog p. 40
LLT-M19-20002F1031
Push-lock · solder
2 pins250 V20 AWire-to-wire≤ 2.5 mm²
Cable Ø 6–10 mm
IP67
Catalog p. 59

Ratings are listed per the corresponding catalog configuration; unstated AC/DC system, wiring order, and protocol require confirmation. The "≤" conductor value is the published upper limit, and the cable outer diameter must fall within the sealing accommodation range.

Dimming and control

Give the dimming signal an independent, clear connection. Beyond pin count, confirm the protocol, shielding and grounding method.

Ports are clearly marked; unused interfaces are capped per the corresponding plan.

Confirm these items first.

  • 0–10 V, DALI, or another control protocol?
  • How many contacts do signal, auxiliary power, and shielding each occupy?
  • Is it bundled with the power cable, and how are length and shield grounding arranged?

Candidate multi-pin examples do not represent protocol certification, nor do they indicate that every dimming system requires 8 contacts. The LLT series name M12 does not imply intermateability with other manufacturers' IEC M12 A-coded interfaces.

Catalog configuration reference · equipment conditions and mating side still to be verified
Part no. / structureContact countRated voltageRated current / contactMounting methodConductor cross section / cable outer diameterProtection / basis
LLT-M12-05008F1051
Threaded · soldered wire
8 contacts60 V5 AWire-to-wire≤ 0.2 mm²
Cable Ø 3.5–6.1 mm
Not listed
Catalog p. 20
LLT-M16-05008F1031
Push-lock · solder
8 contacts110 V5 AWire-to-wire≤ 0.3 mm²
Cable Ø 3.5–8.5 mm
IP67
Catalog p. 40
LLT-M19-05008F1031
Push-lock · solder
8 contacts100 V5 AWire-to-wire≤ 0.5 mm²
Cable Ø 6–10 mm
IP67
Catalog p. 59

Ratings are listed per the corresponding catalog configuration; unstated AC/DC system, wiring order, and protocol require confirmation. The "≤" conductor value is the published upper limit, and the cable outer diameter must fall within the sealing accommodation range.

Branches and distribution

From one trunk line to multiple luminaires. Calculate each branch first, then check the total inlet current and end-of-line voltage drop.

Number the branches; reserve replacement space for faulty branches and avoid suspended cables bearing load.

Confirm these items first.

  • How many inputs and outputs are needed? What is the maximum current per branch?
  • How are simultaneous inlet loads, protective devices, and cable lengths configured?
  • Is the cable outer diameter the same at each cable outlet?

More branches do not raise the permitted inlet current. T/X junction boxes and pluggable distributors are different maintenance approaches; fit a seal for each outlet separately.

Catalog configuration reference · equipment conditions and mating side still to be verified
Part no. / structureContact countRated voltageRated current / contactMounting methodConductor cross section / cable outer diameterProtection / basis
LLT-L25-35003T0001
See catalog for structure · screw-clamp wiring
3 pins250 V35 AT three-way junction box≤ 2.5 mm²
Cable Ø 10–16 mm
IP67
Catalog p. 111
LLT-M16-15002F3254
Threaded · overmolded with cable (soldered)
2 pins250 V10 ADistributor≤ 1 mm²
Cable Ø not listed
IP67
Catalog p. 114

Ratings are listed per the corresponding catalog configuration; unstated AC/DC system, wiring order, and protocol require confirmation. The "≤" conductor value is the published upper limit, and the cable outer diameter must fall within the sealing accommodation range.

What you may want to know before selecting.

Can luminaire power and dimming use the same connector?

A hybrid connector can be evaluated first, but the ratings, insulation and pin assignment of the power and signal contacts must each be verified separately. Splitting into two connectors is also an option, for easier routing and maintenance. Do not decide on total contact count alone.

If the catalog's maximum exceeds my conductor cross section, is termination guaranteed?

Can be included in the initial screening. Also verify the terminal's lower conductor limit, stranding structure and termination process; the cable outer diameter must fall within the seal's accommodation range.

Does IP68 mean it can be used in long-term immersion?

Check the test depth, duration and mated state for the specific model. Spray, washdown and long-term immersion should also be confirmed separately; a single IP marking is not enough.

Application reference and catalog basis

Public equipment information is used to understand circuit roles and does not indicate any supply or intermateability relationship between LLT and the referenced brands.