LLT CONNECTOR SERIES

L25 waterproof connector

Verify pin count, ratings, mounting structure and cable requirements per specific configuration.

Filter this series
Current order number

L25 waterproof connector series appearance reference
Series appearance reference · original product catalog image
Pin positions and structure are confirmed against the drawing specific to the selected configuration.

THE ESSENTIALS

Key specifications

Provide device electrical requirements and installation drawings to confirm the corresponding configuration.

Parameter sources and applicability

Ratings, certifications, and dimensions are confirmed per the selected model. The body dimensions shown do not include device-side mating, cable bend, or tool operating space.

Published parameter summary and limits
Contacts / lockingRated voltageRated currentMounting form
2 pins · 250 V35 AInline junction box
3 pins · 250 V35 AInline junction box
4 contacts · 250 V20 AInline junction box
5 contacts · Verify VVerify AInline junction box
2 pins · 250 V35 AInline junction box
3 pins · 250 V35 AInline junction box
4 contacts · 250 V20 AInline junction box
5 contacts · Verify VVerify AInline junction box
2 pins · 250 V35 AT three-way junction box
3 pins · 250 V35 AT three-way junction box
4 contacts · 250 V20 AT three-way junction box
5 contacts · Verify VVerify AT three-way junction box
2 pins · 250 V35 AX four-way junction box
3 pins · 250 V35 AX four-way junction box
4 contacts · 250 V20 AX four-way junction box
5 contacts · Verify VVerify AX four-way junction box

Values apply to the listed configurations separately. Confirm the complete part number, drawing and installation conditions before ordering; a series maximum is not a rating for every variant. The selector above provides configuration-specific details.

Example of screw termination in a T-junction box. The animation source file is not confirmed to be L25; see the catalog images on this page for the actual L25 product and ordering configurations.

L25 · JUNCTION BOX

Branching, clearly arranged.
Wiring, with something to hold onto.

L25 is available in in-line, T and X configurations. The catalog lists 35 A for 2 / 3 contacts and 20 A for 4 contacts; electrical ratings for the 5-contact configuration require separate confirmation. Select by cable and branch count, then verify termination and sealing.

Select an L25 configuration
L25 original product waterproofing theme display; performance applicability per description

LLT · Environmental protection

Water stays out.Connected inside.

From the mating interface to the cable entry, each seal does its part. A stable path for power and signal in outdoor equipment.

IP67Applicable per selected configuration

Protection applies only after correct mating, locking, and cable sealing are complete. The imagery is an environmental illustration, not footage of actual testing. Applicable conditions ↗

L25 selection questions

What should I confirm before ordering L25?

Confirm the contact count and functions, voltage and current for each circuit, cable conductor size and outside diameter, mounting dimensions, mating part and service environment. Use the published parameter table to narrow the choice, then confirm the complete part number and drawing.

Can L25 connectors with the same contact count mate directly?

Contact count alone does not establish compatibility. Check the interface dimensions, keying, contact gender, locking method and pin assignment against the drawings of both mating parts. Confirm the selected pair with samples where required.

How should I interpret the environmental protection of L25?

Use the rating and test conditions stated for the selected configuration. Sealing depends on the specified mating, locking and cable sealing state. A product illustration or a family name does not establish a test duration, immersion depth or certification for every configuration.

How do I request L25 drawings or a cable assembly?

Provide the equipment interface drawing, circuit requirements, cable length and tolerance, conductor size, jacket diameter, termination requirements and installation environment. The engineering team can then confirm the applicable configuration and documents.

Read technical notes and application limits