M16-YT waterproof connector
Verify pin count, ratings, mounting structure and cable requirements per specific configuration.
See the original drawing for dimensions and structure.
THE ESSENTIALS
Key specifications
Provide device electrical requirements and installation drawings to confirm the corresponding configuration.
Parameter sources and applicability
Ratings, certifications, and dimensions are confirmed per the selected model. The body dimensions shown do not include device-side mating, cable bend, or tool operating space.
Published parameter summary and limits
| Contacts / locking | Rated voltage | Rated current | Mounting form |
|---|---|---|---|
| 2 pins · | 250 V | 10 A | T-type assembly |
| 3 pins · | 250 V | 10 A | T-type assembly |
| 4 contacts · | 250 V | 10 A | T-type assembly |
Values apply to the listed configurations separately. Confirm the complete part number, drawing and installation conditions before ordering; a series maximum is not a rating for every variant. The selector above provides configuration-specific details.

LLT · Environmental protection
Water stays out.Connected inside.
Arrange sealing at each point from the branch interface to the cable entry. Catalog marked IP65; confirm applicability per the equipment's spray environment and correct installation state; not intended as an immersion configuration.
The corresponding catalog page is marked IP65. Protection depends on correct mating, locking, and seal condition, and is not equivalent to IP67 immersion protection. Applicable conditions ↗
Every mounting, clearly seen.
Another angle.
Understand the structure.
Select mounting and contacts first, then take a closer look at the mating face, wiring back end, and catalog dimensional drawings. The appearance of the same structure can be shared; contact count and pin positions are verified independently.

STRUCTURE, IN FOCUS
M16-YT · M16 T-type assembly connector
Appearance, mating face and mounting dimensions are verified separately, so every fit is traceable.
Catalog photo of actual appearance with original watermark retained; the pin count shown in the photo does not automatically represent all configurations.
Select the matching configuration ›No matching appearance for the current filter combination; adjust the mounting or contact conditions.
M16-YT selection questions
What should I confirm before ordering M16-YT?
Confirm the contact count and functions, voltage and current for each circuit, cable conductor size and outside diameter, mounting dimensions, mating part and service environment. Use the published parameter table to narrow the choice, then confirm the complete part number and drawing.
Can M16-YT connectors with the same contact count mate directly?
Contact count alone does not establish compatibility. Check the interface dimensions, keying, contact gender, locking method and pin assignment against the drawings of both mating parts. Confirm the selected pair with samples where required.
How should I interpret the environmental protection of M16-YT?
Use the rating and test conditions stated for the selected configuration. Sealing depends on the specified mating, locking and cable sealing state. A product illustration or a family name does not establish a test duration, immersion depth or certification for every configuration.
How do I request M16-YT drawings or a cable assembly?
Provide the equipment interface drawing, circuit requirements, cable length and tolerance, conductor size, jacket diameter, termination requirements and installation environment. The engineering team can then confirm the applicable configuration and documents.